Steffen Dirkwinkel d7a32c8a1c platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table
[ Upstream commit d6423bd03031c020121da26c41a26bd5cc6d0da3 ]

There are several Beckhoff Automation industrial PC boards which use
pmc_plt_clk* clocks for ethernet controllers. This adds affected boards
to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and
not turned off.

Fixes: 648e921888 ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Signed-off-by: Sasha Levin <sashal@kernel.org>